StacksVerified U.S. regulatory reference

40 CFR Part 98, Table W-1

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov

Industry segment | Source type/component | Emission factor(scf whole gas/hour/unit)

Population Emission Factors—Pneumatic Device Vents and Pneumatic Pumps, Gas Service 1

• Onshore petroleum and natural gas productionContinuous Low Bleed Pneumatic Device Vents 26.8
• Onshore petroleum and natural gas gathering and boostingContinuous High Bleed Pneumatic Device Vents 221
Intermittent Bleed Pneumatic Device Vents 28.8
Pneumatic Pumps 313.3
• Onshore natural gas processingContinuous Low Bleed Pneumatic Device Vents 26.8
• Onshore natural gas transmission compressionContinuous High Bleed Pneumatic Device Vents 230
• Underground natural gas storageIntermittent Bleed Pneumatic Device Vents 22.3
• Natural gas distribution

Population Emission Factors—Major Equipment, Gas Service 1

• Onshore petroleum and natural gas productionWellhead8.87
• Onshore petroleum and natural gas gathering and boostingSeparator9.65
Meters/Piping7.04
Compressor13.8
Dehydrator8.09
Heater5.22
Storage Vessel1.83

Population Emission Factors—Major Equipment, Crude Service

Onshore petroleum and natural gas productionWellhead4.13
Separator4.77
Meters/Piping12.4
Compressor13.8
Dehydrator8.09
Heater3.2
Storage Vessel1.91

Population Emission Factors—Gathering Pipelines, by Material Type 4

Onshore petroleum and natural gas gathering and boostingProtected Steel0.93
Unprotected Steel8.2
Plastic/Composite0.28
Cast Iron8.4

1 For multi-phase flow that includes gas, use the gas service emission factors.

2 Emission factor is in units of “scf whole gas/hour/device.”

3 Emission factor is in units of “scf whole gas/hour/pump.”

4 Emission factors are in units of “scf whole gas/hour/mile of pipeline.”